PB8300-050 (THz Accessory)

  • 제품유형 THz Antennas / Accessories
  • 제품규격 Sample Path-length : 1 - 5 meter
    Operational Bandwidth : 200 - 2500 GHz
  • 브랜드 Bakman Technologies

Product Details

047fb4bbd0b7725313242296138f1143221014.png

 

PB8300-050 Multi-pass Sample Cell for Terahertz Spectroscopy

 

7930ca5052d5ea7e0cb5405fe1bbe259224620.jpg

 

Multi-pass Sample Cell for Terahertz Spectroscopy

 

The Bakman Technologies’ PB8300-050 multi-pass sample cell is specifically designed to work in the sub-mm and THz regime of the electromagnetic spectrum and integrate with the Bakman line of PB7200 and PB7300 frequency domain THz spectrometers. 

With a path-length of up to 5 meters, the cell dramatically increases the detection sensitivity when performing molecular spectroscopy and the athermal design incorporates reflective optics so the instrument remains aligned even with pressure and temperature changes. Further, the coupling optics are integrated into the sample cell so atmospheric gases do not contaminate your measurements.

 

 

Features

 

  •  - Full adjustable path-length up to 4 meters in an enclosure less than 30 cm long.
  •  - Designed so that the entrance and exit beams do not pass through the atmosphere.
  •  - Light weight construction weighing less than 2.5 kg with all of the internal and external components.
  •  - Designed to be athermal for as little impact to fringe spacing as possible.
  •  - 'On the fly' adjustable head spacing to allow fine tuning of the fringe pattern.
  •  - Vacuum sealed enclosure constructed from hard anodized aluminum and carbon fiber.
  •  - Designed for Bakman Technologies photomixers but may be used with other brands
  •  
  •  
  • Applications

  •  
  •  - Microwave and THz Spectroscopy 
  •  - Gas Mixture Analysis and Characterization
  •  
  •  
  • Optical Path

 

2e680aedd70157a8d7e23c2e7f28261f221750.png
  •  

  • Specifications

  •  
  •  

     

    Min

    Typical

    Max

    Units

    Operational Bandwidth

    200

     

    2500

    GHz

    Sample Path-length (approximate)

    1

     

    5

    meters

    Insertion Loss @ 200 GHz **

     

    5

    10

    dB

    Insertion Loss @ 1000 GHz **

     

    5

    10

    dB

    Insertion Loss @ 2200 GHz **

     

    5

    10

    dB

    Vacuum limit

     

    10

     

    mTorr

    Mass ***

     

     

    2.0

    Kg

    Operating Temperature

    -55

     

    85

    C

  • * THz heads, gauges and valves not included. 
  • ** Bakman Technologies photomixers must be used to achieve reported losses. 
  • *** Mass does include THz optics but does not include photomixing heads, gauges nor valves.

 

  